Home > Blog > Content

How to maintain the power booster of a loader?

Nov 10, 2025

1. Structure and working principle of the power booster

The core function of the loader booster (usually referring to the pressure-increasing device or variable pump in the hydraulic system) is to transmit power through hydraulic oil to achieve the lifting, flipping and other actions of the working device (such as the bucket). Its core components include:

Hydraulic pump: Provides pressure oil.

Control valve: Regulates the direction and pressure of oil flow.

Hydraulic cylinder: Converts hydraulic energy into mechanical energy.

Seal: Prevents hydraulic oil leakage.

2. Common Faults and Maintenance Steps

Fault 1: Insufficient or no pressure in the power booster

Cause: The hydraulic pump is worn out or has severe internal leakage.

The viscosity of the hydraulic oil is insufficient or it is contaminated (containing impurities and moisture).

The control valve is stuck or the pressure regulating spring has failed.

The seal is aged or damaged.

Maintenance steps: Check the hydraulic oil: Observe the color of the oil (normally it should be transparent and light yellow; if it turns black or emulsified, it needs to be replaced).

Test the viscosity of the oil (if it is too low, replace it with hydraulic oil that meets the standard).

Inspect the hydraulic pump: Disassemble the pump body and check the wear conditions of the gears, shaft sleeves and end covers.

Replace the severely worn parts, reassemble and then test the pressure.

Clean the control valve: Disassemble the valve body and clean the valve core and valve seat with hydraulic oil.

Replace the pressure regulating spring (if the spring is broken or lacks elasticity).

Replace seals: Inspect O-rings, combination gaskets and other seals, and replace aged or damaged parts.

Fault 2: The power booster operates slowly or intermittently

Cause: Blockage of the hydraulic oil circuit (such as filter element blockage).

Leakage inside the hydraulic cylinder (damage to the piston seal).

The control valve responds slowly (the valve core is stuck).

Maintenance steps: Replace the hydraulic filter element: Remove the filter, clean it or replace it with a new one.

Inspect the hydraulic cylinder: Disassemble the hydraulic cylinder and check whether the piston sealing ring is worn.

After replacing the sealing ring, conduct a sealing performance test.

Debug the control valve: Adjust the valve core clearance to ensure that the valve core moves flexibly.

Clean the oil passage inside the valve body to prevent impurities from getting stuck.

Fault 3: Oil leakage from the power booster

Cause: Damaged seals (such as broken O-rings, loose oil pipe joints).

Shell cracks or sand holes (casting defects).

Maintenance steps: Tighten the joints: Inspect all oil pipe joints and re-tighten them with a wrench.

Replace the sealing parts: Disassemble the leaking area and replace the sealing ring of the corresponding specification.

Repair the shell: If there are cracks in the shell, they can be repaired by welding or gluing (pressure resistance must be ensured).

3. Test after repair

Pressure test: Start the engine, operate the power booster, and use a pressure gauge to check if the system pressure meets the standard.

Action test: Check whether the bucket is lifted and flipped smoothly without any jamming or abnormal noise.

Sealing test: After running for a period of time, check whether there is any oil leakage at each connection point.

4. Preventive maintenance suggestions

Change the hydraulic oil regularly (every 1000 to 2000 working hours).

Clean the hydraulic system (once a year, remove impurities).

Check the seals (once every 500 hours and replace the aged parts in time).

Send Inquiry